COTS and Cloud Platforms

Signalling and other critical functions are moving onto standard hardware and shared infrastructure. The prize is lower lifecycle cost and freedom from bespoke, hard-to-replace equipment; the work is in what safety and security still require of the platform underneath.

Illustration of a system being configured on a shared platform

This is the platform layer - what critical railway operational applications run on and how functional safety is ensured. The interlocking itself is covered under Digital Interlockings, the standardised interfaces between subsystems under EULYNX.

How far the platform shift has come

Running safety-critical signalling on commercial off-the-shelf hardware is no longer theoretical: the first SIL 4 interlocking on COTS hardware entered live operation in 2020, and interlocking and train control functions have since been consolidated onto shared, commercially available platforms. Everything except the field elements themselves can in principle be virtualised.

The attraction for infrastructure managers is lifecycle cost and obsolescence. Bespoke signalling hardware ties a function to a supplier and to a hardware generation; standard platforms decouple the two, so the application and the hardware it runs on can follow separate replacement cycles. This is particularly important for the software-defined functions that are replacing relay and electromechanical interlockings, which have lifecycles of decades while the hardware they run on is replaced every few years.

What does not become standard is the argument. A shared platform has to demonstrate freedom from interference between the applications on it, temporal and spatial isolation, and a patching regime that does not invalidate the approval each time it runs. These are the questions that decide whether a platform migration is an infrastructure project or a safety project.

The platform layer, and what it has to prove

Whether true centralised cloud operation or just COTS hardware in a small, distributed data centre near the tracks, the platform has to prove its safety, security, availability and reliability.

Signalling workloads on standard platforms
Platform engineering

Signalling workloads on standard platforms

Developing rail software applications and moving a signalling application onto standard hardware, virtualised resources, on-premise data centres or (hybrid) cloud infrastructure requires careful consideration of what the application assumes versus what the platform actually guarantees. We help you with that work: establishing the platform's properties, the application's requirements (including SRACs), and the required integration evidence.

  • Software architecture, safety function apportionment and SRAC derivation from the application
  • Development of signalling workloads for COTS environments
  • System integration and testing
Freedom from interference
Safety on shared platforms

Freedom from interference

Putting several applications on one platform is an efficiency gain, but also a safety argument. Temporal and spatial isolation have to be validated, and the evidence has to survive the platform being patched. Establishing what must be demonstrated - and what can be inherited from the platform supplier - keeps the argument tractable.

  • Isolation properties established and tested
  • Application conditions from platform and applications verified
  • Work according to EN 50126, EN 50716 and EN 50129
Hard Real-Time and Timing Faults
Real-time behaviour

Hard Real-Time and Timing Faults

Signalling applications carry hard deadlines: a reaction that arrives late is a failure. On dedicated hardware, timing was a property of the box. On a virtualised, shared platform this requires special design. Scheduler, hypervisor and every neighbouring workload could cause jitter, priority inversion, contention for cores and caches. We establish the deadlines the application actually has, help design mechanisms to enforce deadlines, measure what the platform delivers under peak and overload and work with you on strategies to ensure safety while minimising availability impact, ensuring safe degradation.

  • Deadlines and worst-case response times derived from the application
  • Test scenarios for latency, jitter and timeout behaviour measured under load
  • Analysis of failure modes and effects (FMEA)
System Integrity and Common Cause Failures
Voting is not enough

System Integrity and Common Cause Failures

Composite fail-safety rests on channels that fail independently. Voters can only protect against independent, random failures, not systematic faults which share a common cause among replicas. We trace common cause candidates through the whole software stack and set the separation, diversity and integrity requirements that keep the argument standing.

  • Common cause analysis across hardware, hypervisor, network and operations
  • Independence and diversity requirements for 2oo2 and 2oo3 architectures
  • Data integrity end to end, from storage to the communication protocol
  • Detection mechanisms for loss of integrity and fail-safe operation
Georedundancy and Availability
Availability

Georedundancy and Availability

Georedundancy buys availability and asks new questions. Concentrating what used to be a relay room per station into a handful of data centres concentrates the risk with it: a local outage becomes a regional one. Georedundant sites are the answer, and each of them has a price - distance costs latency, a switchover has to be safe before it is fast, and split brain must be avoided. We support RAMS analysis with a focus on availability of distributed systems, specify switchover, fallback and recovery behaviour that stays fail-safe, and check that the second site does not inherit the failure causes of the first.

  • Availability targets from the RAMS requirements turned into application, platform, site and network requirements
  • Switchover, fallback and split-brain behaviour specified and tested
  • Patching, upgrade and maintenance without losing availability
  • Observability design for monitoring availability and failover
IT-Security and Defence in Depth
Cybersecurity

IT-Security and Defence in Depth

Once signalling shares infrastructure with IT, the attack surface is no longer the cable to the field element. EN 50701 and IEC 62443 provide the frame - zones and conduits, security levels, defence in depth from the perimeter down to the application - and NIS2 takes it to the organisational level. The engineering difficulty is the coupling to the safety case: hardening that does not break an approved configuration, patching fast enough for security and controlled enough for approval, and monitoring that sees into the signalling perimeter without opening a way into it. Systems Lab 21 does not provide IT-Sec advice or services, but works alongside your team to implement the necessary measures.

  • Supporting IT-Security specialists in implementing zones, conduits and security levels per EN 50701 and IEC 62443
  • Co-design of hardening, vulnerability and patch management compatible with approval
  • Enabling security monitoring and incident response for the signalling perimeter
Digital Sovereignty
Who controls the platform you depend on

Digital Sovereignty

A platform decision is a dependency decision: on a supplier's roadmap and licence terms, on a control plane operated somewhere else, on a software package with a sole maintainer or on a jurisdiction whose access laws are not yours. In short: your entire supply chain can pose risks. For critical infrastructure that question is not small print during procurement - it is a matter of legislation and requirements. The European Commission and national institutions such as the BSI (Bundesamt für Sicherheit in der Informationstechnik) have developed guidelines and frameworks for digital sovereignty - like the Sovereignty Effective Assurance Level (SEAL). Architecture rather than contract clauses protects your assets: open interfaces and data models, open source where it removes lock-in without causing supply chain risk, deployments that can move between on-premise, private and sovereign cloud, disaster recovery designed not just for floods and fires, but also political change and foreign interference.

  • Open standards and open source components
  • Deployments portable across on-premise, private and sovereign cloud
  • Source, build pipeline and know-how in your hands

Services

What we deliver on these projects, for infrastructure managers and for suppliers.

Platform Integration

Platform Integration

COTS and cloud platforms integrated into your signalling landscape.

Book a free consultation
Diagnosis Platforms

Diagnosis Platforms

Diagnostic and condition-monitoring systems connected to the systems that use them.

Interfaces and Protocols

Interfaces and Protocols

Connectivity, parametrisation, system boundaries, circuit breakers and interface contracts.

Test Environments

Test Environments

Distributed test setups that mirror the platform your system will run on.

Discover Platform21
Application Development

Application Development

The signalling applications that run on the platform, developed to the CENELEC process where the function is safety-related.

Platform Development

Platform Development

Building the platform layer itself, from runtime environment to deployment and operation.

Book a free consultation

Looks useful to you?

Get in touch with us to discuss how our products can enhance your capabilities best.

  • Experts in Rail
  • Traditionally Reliable
  • Natively Digital